30 April 2025
Savannah Resources Plc
(AIM: SAV) ('Savannah', or the 'Company')
Drilling confirms zones of near surface higher-grade lithium mineralisation at Pinheiro and Reservatório
Savannah Resources plc, the developer of the Barroso Lithium Project (the 'Project') in Portugal, a 'Strategic Project' under the European Critical Raw Materials Act and Europe's largest spodumene lithium deposit, is pleased to announce the second batch of assay results from Phase 2 of its Definitive Feasibility Study ('DFS') drilling programme at the Project. The 117-hole, c.13,000m programme is being undertaken for further JORC Resource definition, geotechnical and metallurgical purposes.
Highlights:
· The Phase 2 drill programme for the DFS is well underway, targeting the Pinheiro, Reservatório and Grandão deposits.
· To date, 75 holes have been drilled for c. 8,300m in the planned 117 hole/c.13,000m programme.
· New significant lithium assays have been received from a further 22 holes (5 at Pinheiro, 12 at Reservatório and 5 at Grandão). Assays from 42 holes have now been received to date overall.
· The initial stage of the Phase 2 drilling is nearing completion and the results from this will feed into upgrading the confidence level of the JORC Resource estimates for each deposit.
· At Pinheiro, broad zones of near surface, higher grade lithium mineralisation are now being intersected on a regular basis. Better intersections include:
o 20.76m @ 1.48% Li2O from 44.62m in hole 25PNRDD011, including 9m @ 1.87% Li2O
o 31.04m @ 1.46% Li2O from 65.96m in hole 25PNRDD013, including 14m @ 1.73% Li2O and 12m @ 1.39% Li2O
· At Reservatório, the latest assays are indicating zones of higher-grade mineralisation, including some near surface. Better intersections include:
o 27m @ 1.25% Li2O from 100m in hole 25RESRC050, including 2m @ 2.02% Li2O, 8.9m @ 1.33% Li2O and 10m @ 1.4% Li2O
o 22m @ 1.56% Li2O from 25m in hole 25RESRC064, including 9m @ 2.00% Li2O, 3m @ 1.68% Li2O and 2m @ 1.42% Li2O
o 22m @ 1.51% Li2O from 64m in hole 25RESRC058, including 10m @ 2.00% Li2O and 6m @ 2.89% Li2O
o 22m @ 1.35% Li2O from 65m in hole 25RESRC060, including 6m @ 1.68% Li2O and 3m @ 1.72% Li2O
· Recent results from Grandão confirm that mineralisation continues along strike and down dip with better intersections including:
o 13m @ 1.14% Li2O from 3m in hole 25GRARC140, including 4m @ 1.62% Li2O
Savannah's Technical Director, Dale Ferguson said, "We have made good progress to date with our field programme as we move towards the conclusion of the Phase 2 DFS drilling. We are particularly encouraged by the continued higher-grade zones of lithium mineralisation we are now consistently encountering at the Pinheiro deposit. We plan to mine Pinheiro very early in Project's development, so any increase in the average grade and size of this orebody could have a positive impact on operating costs and cash flow generation in the Project's first years, and therefore the Project's overall economics.
"This second batch of drilling results has also highlighted zones of higher-grade mineralisation at Reservatório with one being intersected only 25m down hole. The drilling is continuing to build our confidence in the grades and tonnages of the existing JORC Resource estimates and the results are pointing towards the continued expansion of the resources both along strike and down dip.
"This Project continues to reveal strong signs of its greater resource potential which, aside from affirming our early assumptions, confirms why this project is of increasingly strategic importance to Europe. The team and I look forward to reporting further results over the coming months as we move towards the production of new JORC Resource estimates for these orebodies as part of the Project's DFS. Busy and exciting times lie ahead for Savannah."
Further Information
As previously announced, Savannah started Phase 2 of the DFS-related drilling programme at the Barroso Lithium Project in January 2025 (see Figure 1). The programme consists of drilling for resource, metallurgical and geotechnical purposes using primarily Reverse Circulation ('RC') rigs with some supplementary diamond drilling. To date, 8,302m of drilling has been completed of the c.13,000m initially planned for Phase 2. The programme is ongoing, and updates will be provided as further results are received.
Figure 1. Barroso Lithium Project summary map showing deposits and drill hole locations.
Pinheiro
The current JORC Resource estimate for the Pinheiro deposit (all Inferred as at May 2024) is 2.0Mt at 1.0% Li2O.
The drilling at Pinheiro is building on the Phase 1 DFS programme completed last year, and is continuing to focus on infilling the previous drill programme carried out in 2018. Recent results show that the Eastern Pegmatite continues to carry ore grade lithium mineralisation at depth, with the thickness of the pegmatite generally increasing, although there is some variability along strike. The drilling has focussed on the northern and central section of the pegmatite, which has shown some variability in the orientation in terms of the trend direction and direction of dip, providing a challenge for targeting of the drilling. However, the latest drilling has shown that the Eastern Pegmatite extends to the northeast, with further drilling being considered dependant on results. A drill hole designed for geotechnical purposes (25PNRDD011) contained a significant intersection of pegmatite which returned 20.76m at 1.48% Li2O from 44.62m.
Two holes were completed on the southern extent of the Western Pegmatite with one hole down dip of the previously reported 25PNRRC030, which intersected high grade lithium mineralisation across the width of the pegmatite (24m at 1.17% Li2O from 11m and 28m at 1.21% Li2O from 38m). The diamond drill hole 25PNRDD013 drilled about 50m down dip of 25PNRRC030 continued with high grades over the width of the pegmatite intercept (33.04m at 1.46% Li2O), highlighting the increased potential at depth. The Western Pegmatite also remains open along strike to the south.
Significant recent lithium mineralisation intersections at Pinheiro include:
o 20.76m @ 1.48% Li2O from 44.62m in hole 25PNRDD011, including 9m @ 1.87% Li2O
o 31.04m @ 1.46% Li2O from 65.96m in hole 25PNRDD013, including 14m @ 1.73% Li2O and 12m @ 1.39% Li2O
Figure 2. Location of Phase 2 diamond drilling at Pinheiro with significant intercepts to date.
Figure 3. Cross section 1 Eastern Pegmatite of Pinheiro deposit (Section A-A').
Figure 4. Cross section 2 Western Pegmatite of Pinheiro deposit (Section B-B').
Reservatório
The current JORC Resource estimate for the Reservatório deposit (Indicated & Inferred as at May 2024) is 4.2Mt at 0.9% Li2O.
Drilling at Reservatório continues to test the down dip and eastern extremities of the pegmatite and continues to demonstrate the extension of the lithium mineralisation beyond the designed mining parameters. Numerous lithium intercepts were returned above the current average for the orebody of 0.9% Li2O. While the drilling has shown that there is possibly some structural disruption to the pegmatite including several broken zones within the pegmatite indicating possible faulting offsetting the structure and some natural variability to the geometry of the pegmatite, there is suggestion that the pegmatite continues beyond the present planned programme.
Significant mineralised intersections at Reservatório include:
o 30.15m @ 1.15% Li2O from 129.85m in hole 25RESRC049, including 3m @ 1.46% Li2O, 6.2m @ 1.79% Li2O and 5m @ 1.58% Li2O
o 27m @ 1.25% Li2O from 100m in hole 25RESRC050, including 2m @ 2.02% Li2O, 8.9m @ 1.33% Li2O and 10m @ 1.4% Li2O
o 22m @ 1.56% Li2O from 25m in hole 25RESRC064, including 9m @ 2% Li2O, 3m @ 1.68% Li2O and 2m @ 1.42% Li2O
o 22m @ 1.51% Li2O from 64m in hole 25RESRC058, including 10m @ 2.00% Li2O and 6m @ 2.89% Li2O
o 22m @ 1.35% Li2O from 65m in hole 25RESRC060, including 6m @ 1.68% Li2O and 3m @ 1.72% Li2O
o 18.06m @ 0.82% Li2O from 136.94m in hole 25RESRC048, including 3m @ 1.29% Li2O
o 13m @ 1.11% Li2O from 105m in hole 25RESRC065, including 2m @ 1.66% Li2O
o 13m @ 1.01% Li2O from 159m in hole 25RESRC048, including 5.2m @ 1.30% Li2O
The drilling operations at Reservatório are ongoing (Figures 5 and 6).
Figure 5. Location of Phase 2 diamond drilling at Reservatório with significant intercepts.
Figure 6. Cross section of Reservatório deposit (Section A - A').
Grandão
The current JORC Resource estimate for the Grandão deposit (Measured, Indicated & Inferred as at May 2024) is 17.7Mt at 1.04% Li2O.
The drilling at Grandão has continued to focus primarily on the southern extremities of the pegmatite and where it occurs nearer to the surface and will be part of the preliminary mining stages. The drilling has shown that the southern edge is thinner than the central part of the pegmatite with widths varying between 3m to 20m.
The bulk of the Grandão resource has already been classified in the Indicated or Measured category and this round of drilling is giving more confidence to the southern and northern extents of the pegmatite to aid in mine design.
Significant mineralised intersections at Grandão include:
o 13m @ 1.14% Li2O from 3m in hole 25GRARC140, including 4m @ 1.62% Li2O
o 19m @ 0.64% Li2O from 15m in hole 25GRARC141, including 6m @ 1.56% Li2O
o 12m @ 0.99% Li2O from 47m in hole 25GRARC141, including 4m @ 1.45% Li2O
Figure 9. Location of Phase 2 drilling at Grandão with significant intercepts from assays results.
Next steps
The initial stage of the Phase 2 drilling is nearing completion and the results from this will feed into upgrading the confidence level of the JORC Resource estimates for each deposit.
In conjunction with resource drilling, preparation of the specific requirements of core samples for metallurgical testing has commenced. Once results have been received the specific sample requirements requested by Savannah's metallurgical consultants will be sorted and sent for testing.
The drilling of diamond drill holes for geotechnical testing is complete at Pinheiro and is currently being carried out at Grandão before being undertaken at Reservatório. The results from this programme will be used to aid in the design of the various mining pits to ensure maximum extraction of ore under safe and stable conditions.
Competent Person and Regulatory Information
The information in this announcement that relates to exploration results is based upon information compiled by Mr Dale Ferguson, Technical Director of Savannah Resources Limited. Mr Ferguson is a Member of the Australasian Institute of Mining and Metallurgy (AusIMM) and has sufficient experience which is relevant to the style of mineralisation and type of deposit under consideration and to the activity which he is undertaking to qualify as a Competent Person as defined in the December 2012 edition of the "Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore Reserves" (JORC Code). Mr Ferguson consents to the inclusion in the report of the matters based upon the information in the form and context in which it appears.
Regulatory Information
This Announcement contains inside information for the purposes of the UK version of the market abuse regulation (EU No. 596/2014) as it forms part of United Kingdom domestic law by virtue of the European Union (Withdrawal) Act 2018 ("UK MAR").
Savannah - Enabling Europe's energy transition.
**ENDS**
Follow @ SavannahRes on X (Formerly known as Twitter)
Follow Savannah Resources on LinkedIn
For further information please visit www.savannahresources.com or contact:
Savannah Resources PLC Emanuel Proença, CEO |
Tel: 44 20 7117 2489
|
SP Angel Corporate Finance LLP (Nominated Advisor & Broker) David Hignell/ Charlie Bouverat (Corporate Finance) Grant Barker/Abigail Wayne (Sales & Broking)
|
Tel: 44 20 3470 0470
|
Canaccord Genuity Limited (Joint Broker) James Asensio / Charlie Hammond (Corporate Broking) Ben Knott (Sales) |
Tel: 44 20 7523 8000
|
Camarco (UK Financial PR) Gordon Poole/ Emily Hall / Nuthara Bandara |
Tel: 44 20 3757 4980 |
Portugal Media Relations Antonio Neves Costa, Communications Manager |
Tel: 351 962 678 912 |
|
|
About Savannah
Savannah Resources is a mineral resource development company and the sole owner of the Barroso Lithium Project (the 'Project') in northern Portugal. The Project is the largest battery grade spodumene lithium resource outlined to date in Europe and was classified as a 'Strategic Project' by the European Commission under the Critical Raw Materials Act in March 2025.
Through the Project, Savannah will help Portugal to play an important role in providing a long-term, locally sourced, lithium raw material supply for Europe's lithium battery value chain. Once in operation the Project will produce enough lithium (contained in c.190,000tpa of spodumene concentrate) for approximately half a million vehicle battery packs per year and hence make a significant contribution towards the European Commission's Critical Raw Material Act goal of a minimum 10% of European endogenous lithium production from 2030.
Savannah is focused on the responsible development and operation of the Barroso Lithium Project so that its impact on the environment is minimised and the socio-economic benefits that it can bring to all its stakeholders are maximised.
The Company is listed and regulated on the London Stock Exchange's Alternative Investment Market (AIM) and trades under the ticker "SAV".
Hole ID |
Prospect |
Hole Type |
Tot Depth (m) |
Easting |
Northing |
RL |
Dip |
Azimuth |
||
25GRADD048 |
Grandão |
DD |
128.25 |
601650 |
4607783 |
567 |
-50 |
190 |
||
25GRADD049 |
Grandão |
DD |
120.7 |
601516 |
4607909 |
507 |
-50 |
230 |
||
25GRARC134 |
Grandão |
RC |
30 |
601928 |
4607805 |
578 |
-90 |
0 |
||
25GRARC135 |
Grandão |
RC |
50 |
601889 |
4607672 |
587 |
-90 |
0 |
||
25GRARC136 |
Grandão |
RC |
40 |
601884 |
4607651 |
595 |
-90 |
0 |
||
25GRARC137 |
Grandão |
RC |
80 |
601772 |
4607635 |
606 |
-90 |
0 |
||
25GRARC138 |
Grandão |
RC |
80 |
601776 |
4607634 |
606 |
-60 |
90 |
||
25GRARC139 |
Grandão |
RC |
84 |
601803 |
4607696 |
577 |
-90 |
0 |
||
25GRARC140 |
Grandão |
RCDD |
28.6 |
601817 |
4607719 |
562 |
-90 |
0 |
||
25GRARC141 |
Grandão |
RC |
90 |
601787 |
4607763 |
551 |
-72 |
90 |
||
25GRARC142 |
Grandão |
RCDD |
49 |
601734 |
4607675 |
596 |
-60 |
90 |
||
25GRARC143 |
Grandão |
RCDD |
50 |
601732 |
4607675 |
597 |
-90 |
0 |
||
25GRARC144 |
Grandão |
RC |
170 |
601730 |
4607716 |
582 |
-70 |
90 |
||
25GRARC145 |
Grandão |
RC |
142 |
601729 |
4607716 |
582 |
-90 |
0 |
||
25GRARC146 |
Grandão |
RCDD |
122.25 |
601634 |
4608025 |
504 |
-60 |
120 |
||
25GRARC147 |
Grandão |
RC |
141 |
601742 |
4608055 |
539 |
-65 |
45 |
||
25PNRDD009 |
Pinheiro |
DD |
84.85 |
601594 |
4606830 |
580 |
-60 |
270 |
||
25PNRDD010 |
Pinheiro |
DD |
110.35 |
601590 |
4606831 |
584 |
-57 |
215 |
||
25PNRDD011 |
Pinheiro |
DD |
120.75 |
601583 |
4606909 |
575 |
-50 |
263 |
||
25PNRDD012 |
Pinheiro |
DD |
101.2 |
601579 |
4606910 |
575 |
-50 |
63 |
||
25PNRDD013 |
Pinheiro |
DD |
124.9 |
601399 |
4606803 |
538 |
-60 |
90 |
||
25PNRDD014 |
Pinheiro |
DD |
111.8 |
601414 |
4606856 |
561 |
-50 |
185 |
||
25PNRDD015 |
Pinheiro |
DD |
126.8 |
601598 |
4607011 |
583 |
-50 |
310 |
||
25PNRDD016 |
Pinheiro |
DD |
108.3 |
601399 |
4606802 |
538 |
-50 |
110 |
||
25PNRDD017 |
Pinheiro |
DD |
100.1 |
601599 |
4607011 |
583 |
-62 |
310 |
||
25PNRDD018 |
Pinheiro |
DD |
179.55 |
601637 |
4606994 |
572 |
-55 |
230 |
||
25PNRRC026 |
Pinheiro |
RCDD |
120 |
601607 |
4606920 |
573 |
-70 |
270 |
||
25PNRRC027 |
Pinheiro |
RC |
100 |
601578 |
4606879 |
581 |
-90 |
0 |
||
25PNRRC028 |
Pinheiro |
RCDD |
94.3 |
601577 |
4606879 |
581 |
-80 |
270 |
||
25PNRRC029 |
Pinheiro |
RC |
70 |
601575 |
4606878 |
581 |
-60 |
270 |
||
25PNRRC030 |
Pinheiro |
RC |
70 |
601430 |
4606800 |
554 |
-60 |
90 |
||
25PNRRC031 |
Pinheiro |
RCDD |
128.55 |
601599 |
4607010 |
583 |
-60 |
245 |
||
25PNRRC032 |
Pinheiro |
RC |
100 |
601639 |
4607036 |
584 |
-60 |
270 |
||
25PNRRC033 |
Pinheiro |
RCDD |
131.5 |
601636 |
4606995 |
573 |
-60 |
270 |
||
25PNRRC034 |
Pinheiro |
RC |
85 |
601664 |
4607061 |
591 |
-60 |
270 |
||
25PNRRC035 |
Pinheiro |
RC |
110 |
601589 |
4606977 |
572 |
-60 |
270 |
||
25RESRC046 |
Reservatório |
RCDD |
184.8 |
599583 |
4609279 |
639 |
-80 |
150 |
||
25RESRC047 |
Reservatório |
RCDD |
178.7 |
599585 |
4609275 |
639 |
-65 |
150 |
||
25RESRC048 |
Reservatório |
RCDD |
186.5 |
599498 |
4609187 |
641 |
-90 |
0 |
||
25RESRC049 |
Reservatório |
RCDD |
174 |
599500 |
4609184 |
641 |
-70 |
150 |
||
25RESRC050 |
Reservatório |
RCDD |
140.1 |
599520 |
4609147 |
631 |
-63 |
150 |
||
25RESRC051 |
Reservatório |
RCDD |
160.4 |
599618 |
4609287 |
620 |
-80 |
150 |
||
Hole ID |
Prospect |
Hole Type |
Tot Depth (m) |
Easting |
Northing |
RL |
Dip |
Azimuth |
||
25RESRC052 |
Reservatório |
RCDD |
158.8 |
599620 |
4609285 |
619 |
-70 |
150 |
||
25RESRC053 |
Reservatório |
RC |
111 |
599695 |
4609242 |
613 |
-90 |
0 |
||
25RESRC054 |
Reservatório |
RCDD |
150.4 |
599656 |
4609309 |
604 |
-90 |
0 |
||
25RESRC055 |
Reservatório |
RCDD |
105 |
599657 |
4609306 |
604 |
-70 |
150 |
||
25RESRC056 |
Reservatório |
RCDD |
88 |
599913 |
4609253 |
577 |
-80 |
0 |
||
25RESRC057 |
Reservatório |
RC |
88 |
599915 |
4609247 |
577 |
-60 |
140 |
||
25RESRC058 |
Reservatório |
RCDD |
96 |
599710 |
4609302 |
593 |
-80 |
150 |
||
25RESRC059 |
Reservatório |
RC |
100 |
599950 |
4609211 |
586 |
-60 |
150 |
||
25RESRC060 |
Reservatório |
RC |
147 |
599712 |
4609299 |
593 |
-60 |
150 |
||
25RESRC061 |
Reservatório |
RC |
120 |
599783 |
4609267 |
588 |
-70 |
310 |
||
25RESRC062 |
Reservatório |
RC |
120 |
599784 |
4609266 |
588 |
-90 |
0 |
||
25RESRC063 |
Reservatório |
RC |
67 |
599934 |
4609230 |
581 |
-60 |
150 |
||
25RESRC064 |
Reservatório |
RC |
55 |
599970 |
4609238 |
575 |
-60 |
150 |
||
25RESRC065 |
Reservatório |
RC |
140 |
599503 |
4609102 |
617 |
-60 |
150 |
||
25RESRC066 |
Reservatório |
RC |
70 |
599970 |
4609241 |
575 |
-80 |
0 |
||
25RESRC067 |
Reservatório |
RCDD |
160.8 |
599481 |
4609136 |
628 |
-65 |
150 |
||
25RESRC068 |
Reservatório |
RC |
94 |
599968 |
4609241 |
575 |
-60 |
340 |
||
25RESRC069 |
Reservatório |
RC |
91 |
599901 |
4609215 |
594 |
-60 |
150 |
||
25RESRC070 |
Reservatório |
RC |
100 |
599888 |
4609236 |
589 |
-60 |
150 |
||
25RESRC071 |
Reservatório |
RCDD |
143 |
599480 |
4609138 |
628 |
-75 |
150 |
||
25RESRC072 |
Reservatório |
RC |
85 |
599889 |
4609238 |
589 |
-90 |
0 |
||
25RESRC073 |
Reservatório |
RCDD |
177.25 |
599479 |
4609139 |
628 |
-85 |
150 |
||
25RESRC074 |
Reservatório |
RC |
90 |
599586 |
4609050 |
607 |
-60 |
150 |
||
25RESRC075 |
Reservatório |
RCDD |
85 |
599863 |
4609275 |
579 |
-70 |
150 |
||
25RESRC076 |
Reservatório |
RC |
100 |
599568 |
4609080 |
614 |
-60 |
150 |
||
25RESRC077 |
Reservatório |
RC |
105 |
599566 |
4609082 |
614 |
-80 |
150 |
||
25RESRC078 |
Reservatório |
RCDD |
91 |
599863 |
4609276 |
579 |
-90 |
0 |
||
25RESRC079 |
Reservatório |
RC |
121 |
599733 |
4609259 |
603 |
-60 |
150 |
||
25RESRC080 |
Reservatório |
RC |
122 |
599800 |
4609219 |
606 |
-60 |
150 |
||
25RESRC081 |
Reservatório |
RC |
133 |
599799 |
4609221 |
606 |
-90 |
0 |
||
25RESRC082 |
Reservatório |
RC |
147 |
599801 |
4609224 |
606 |
-70 |
330 |
||
25RESRC083 |
Reservatório |
RC |
107 |
599852 |
4609221 |
600 |
-60 |
150 |
||
25RESRC084 |
Reservatório |
RC |
111 |
599852 |
4609222 |
600 |
-90 |
0 |
||
25GRADD048 |
Grandão |
DD |
128.25 |
601650 |
4607783 |
567 |
-50 |
190 |
||
25GRADD049 |
Grandão |
DD |
120.7 |
601516 |
4607909 |
507 |
-50 |
230 |
||
25GRARC134 |
Grandão |
RC |
30 |
601928 |
4607805 |
578 |
-90 |
0 |
||
25GRARC135 |
Grandão |
RC |
50 |
601889 |
4607672 |
587 |
-90 |
0 |
||
25GRARC136 |
Grandão |
RC |
40 |
601884 |
4607651 |
595 |
-90 |
0 |
||
25GRARC137 |
Grandão |
RC |
80 |
601772 |
4607635 |
606 |
-90 |
0 |
||
25GRARC138 |
Grandão |
RC |
80 |
601776 |
4607634 |
606 |
-60 |
90 |
||
25GRARC139 |
Grandão |
RC |
84 |
601803 |
4607696 |
577 |
-90 |
0 |
||
25GRARC140 |
Grandão |
RCDD |
28.6 |
601817 |
4607719 |
562 |
-90 |
0 |
||
25GRARC141 |
Grandão |
RC |
90 |
601787 |
4607763 |
551 |
-72 |
90 |
||
25GRARC142 |
Grandão |
RCDD |
49 |
601734 |
4607675 |
596 |
-60 |
90 |
||
Hole ID |
Prospect |
Hole Type |
Tot Depth (m) |
Easting |
Northing |
RL |
Dip |
Azimuth |
||
25GRARC143 |
Grandão |
RCDD |
50 |
601732 |
4607675 |
597 |
-90 |
0 |
||
25GRARC144 |
Grandão |
RC |
170 |
601730 |
4607716 |
582 |
-70 |
90 |
||
25GRARC145 |
Grandão |
RC |
142 |
601729 |
4607716 |
582 |
-90 |
0 |
||
25GRARC146 |
Grandão |
RCDD |
122.25 |
601634 |
4608025 |
504 |
-60 |
120 |
||
25GRARC147 |
Grandão |
RC |
141 |
601742 |
4608055 |
539 |
-65 |
45 |
||
25PNRDD009 |
Pinheiro |
DD |
84.85 |
601594 |
4606830 |
580 |
-60 |
270 |
||
25PNRDD010 |
Pinheiro |
DD |
110.35 |
601590 |
4606831 |
584 |
-57 |
215 |
||
25PNRDD011 |
Pinheiro |
DD |
120.75 |
601583 |
4606909 |
575 |
-50 |
263 |
||
25PNRDD012 |
Pinheiro |
DD |
101.2 |
601579 |
4606910 |
575 |
-50 |
63 |
||
25PNRDD013 |
Pinheiro |
DD |
124.9 |
601399 |
4606803 |
538 |
-60 |
90 |
||
25PNRDD014 |
Pinheiro |
DD |
111.8 |
601414 |
4606856 |
561 |
-50 |
185 |
||
25PNRDD015 |
Pinheiro |
DD |
126.8 |
601598 |
4607011 |
583 |
-50 |
310 |
||
25PNRDD016 |
Pinheiro |
DD |
108.3 |
601399 |
4606802 |
538 |
-50 |
110 |
||
25PNRDD017 |
Pinheiro |
DD |
100.1 |
601599 |
4607011 |
583 |
-62 |
310 |
||
25PNRDD018 |
Pinheiro |
DD |
179.55 |
601637 |
4606994 |
572 |
-55 |
230 |
||
25PNRRC026 |
Pinheiro |
RCDD |
120 |
601607 |
4606920 |
573 |
-70 |
270 |
||
25PNRRC027 |
Pinheiro |
RC |
100 |
601578 |
4606879 |
581 |
-90 |
0 |
||
25PNRRC028 |
Pinheiro |
RCDD |
94.3 |
601577 |
4606879 |
581 |
-80 |
270 |
||
25PNRRC029 |
Pinheiro |
RC |
70 |
601575 |
4606878 |
581 |
-60 |
270 |
||
25PNRRC030 |
Pinheiro |
RC |
70 |
601430 |
4606800 |
554 |
-60 |
90 |
||
25PNRRC031 |
Pinheiro |
RCDD |
128.55 |
601599 |
4607010 |
583 |
-60 |
245 |
||
25PNRRC032 |
Pinheiro |
RC |
100 |
601639 |
4607036 |
584 |
-60 |
270 |
||
25PNRRC033 |
Pinheiro |
RCDD |
131.5 |
601636 |
4606995 |
573 |
-60 |
270 |
||
25PNRRC034 |
Pinheiro |
RC |
85 |
601664 |
4607061 |
591 |
-60 |
270 |
||
25PNRRC035 |
Pinheiro |
RC |
110 |
601589 |
4606977 |
572 |
-60 |
270 |
||
25RESRC046 |
Reservatório |
RCDD |
184.8 |
599583 |
4609279 |
639 |
-80 |
150 |
||
25RESRC047 |
Reservatório |
RCDD |
178.7 |
599585 |
4609275 |
639 |
-65 |
150 |
||
25RESRC048 |
Reservatório |
RCDD |
186.5 |
599498 |
4609187 |
641 |
-90 |
0 |
||
25RESRC049 |
Reservatório |
RCDD |
174 |
599500 |
4609184 |
641 |
-70 |
150 |
||
25RESRC050 |
Reservatório |
RCDD |
140.1 |
599520 |
4609147 |
631 |
-63 |
150 |
||
25RESRC051 |
Reservatório |
RCDD |
160.4 |
599618 |
4609287 |
620 |
-80 |
150 |
||
25RESRC052 |
Reservatório |
RCDD |
158.8 |
599620 |
4609285 |
619 |
-70 |
150 |
||
25RESRC053 |
Reservatório |
RC |
111 |
599695 |
4609242 |
613 |
-90 |
0 |
||
25RESRC054 |
Reservatório |
RCDD |
150.4 |
599656 |
4609309 |
604 |
-90 |
0 |
||
25RESRC055 |
Reservatório |
RCDD |
105 |
599657 |
4609306 |
604 |
-70 |
150 |
||
25RESRC056 |
Reservatório |
RCDD |
88 |
599913 |
4609253 |
577 |
-80 |
0 |
||
25RESRC057 |
Reservatório |
RC |
88 |
599915 |
4609247 |
577 |
-60 |
140 |
||
25RESRC058 |
Reservatório |
RCDD |
96 |
599710 |
4609302 |
593 |
-80 |
150 |
||
25RESRC059 |
Reservatório |
RC |
100 |
599950 |
4609211 |
586 |
-60 |
150 |
||
25RESRC060 |
Reservatório |
RC |
147 |
599712 |
4609299 |
593 |
-60 |
150 |
||
25RESRC061 |
Reservatório |
RC |
120 |
599783 |
4609267 |
588 |
-70 |
310 |
||
25RESRC062 |
Reservatório |
RC |
120 |
599784 |
4609266 |
588 |
-90 |
0 |
||
25RESRC063 |
Reservatório |
RC |
67 |
599934 |
4609230 |
581 |
-60 |
150 |
||
Hole ID |
Prospect |
Hole Type |
Tot Depth (m) |
Easting |
Northing |
RL |
Dip |
Azimuth |
||
25RESRC064 |
Reservatório |
RC |
55 |
599970 |
4609238 |
575 |
-60 |
150 |
||
25RESRC065 |
Reservatório |
RC |
140 |
599503 |
4609102 |
617 |
-60 |
150 |
||
25RESRC066 |
Reservatório |
RC |
70 |
599970 |
4609241 |
575 |
-80 |
0 |
||
25RESRC067 |
Reservatório |
RCDD |
160.8 |
599481 |
4609136 |
628 |
-65 |
150 |
||
25RESRC068 |
Reservatório |
RC |
94 |
599968 |
4609241 |
575 |
-60 |
340 |
||
25RESRC069 |
Reservatório |
RC |
91 |
599901 |
4609215 |
594 |
-60 |
150 |
||
25RESRC070 |
Reservatório |
RC |
100 |
599888 |
4609236 |
589 |
-60 |
150 |
||
25RESRC071 |
Reservatório |
RCDD |
143 |
599480 |
4609138 |
628 |
-75 |
150 |
||
25RESRC072 |
Reservatório |
RC |
85 |
599889 |
4609238 |
589 |
-90 |
0 |
||
25RESRC073 |
Reservatório |
RCDD |
177.25 |
599479 |
4609139 |
628 |
-85 |
150 |
||
25RESRC074 |
Reservatório |
RC |
90 |
599586 |
4609050 |
607 |
-60 |
150 |
||
25RESRC075 |
Reservatório |
RCDD |
85 |
599863 |
4609275 |
579 |
-70 |
150 |
||
25RESRC076 |
Reservatório |
RC |
100 |
599568 |
4609080 |
614 |
-60 |
150 |
||
25RESRC077 |
Reservatório |
RC |
105 |
599566 |
4609082 |
614 |
-80 |
150 |
||
25RESRC078 |
Reservatório |
RCDD |
91 |
599863 |
4609276 |
579 |
-90 |
0 |
||
25RESRC079 |
Reservatório |
RC |
121 |
599733 |
4609259 |
603 |
-60 |
150 |
||
25RESRC080 |
Reservatório |
RC |
122 |
599800 |
4609219 |
606 |
-60 |
150 |
||
25RESRC081 |
Reservatório |
RC |
133 |
599799 |
4609221 |
606 |
-90 |
0 |
||
25RESRC082 |
Reservatório |
RC |
147 |
599801 |
4609224 |
606 |
-70 |
330 |
||
25RESRC083 |
Reservatório |
RC |
107 |
599852 |
4609221 |
600 |
-60 |
150 |
||
25RESRC084 |
Reservatório |
RC |
111 |
599852 |
4609222 |
600 |
-90 |
0 |
||
Hole ID |
Prospect |
From |
To |
Width |
Li20 |
25GRARC137 |
Grandão |
50 |
53 |
3 |
1.42 |
25GRARC138 |
Grandão |
No significant results |
|||
25GRARC139 |
Grandão |
10 |
13 |
3 |
0.7 |
and |
Grandão |
19 |
26 |
7 |
0.82 |
and |
Grandão |
55 |
57 |
2 |
1.51 |
and |
Grandão |
61 |
64 |
3 |
1.04 |
25GRARC140 |
Grandão |
3 |
16 |
13 |
1.14 |
25GRARC141 |
Grandão |
15 |
23 |
8 |
1.27 |
and |
Grandão |
31 |
34 |
3 |
0.62 |
and |
Grandão |
47 |
59 |
12 |
0.99 |
and |
Grandão |
68 |
71 |
3 |
0.87 |
25PNRDD011 |
Pinheiro |
32 |
34 |
2 |
1.29 |
and |
Pinheiro |
40 |
42 |
2 |
1.19 |
and |
Pinheiro |
44.62 |
65.38 |
20.76 |
1.48 |
25PNRDD013 |
Pinheiro |
65.96 |
97 |
31.04 |
1.46 |
25PNRRC031 |
Pinheiro |
8 |
10 |
2 |
1.2 |
and |
Pinheiro |
16 |
20 |
4 |
1.64 |
and |
Pinheiro |
91 |
97.8 |
6.8 |
1.19 |
25PNRRC032 |
Pinheiro |
7 |
18 |
11 |
0.98 |
25RESRC047** |
Reservatório |
169.27 |
172 |
2.73 |
1.06 |
25RESRC048 |
Reservatório |
136.94 |
155 |
18.06 |
0.82 |
and |
Reservatório |
159 |
172 |
13 |
1.01 |
25RESRC049 |
Reservatório |
129.85 |
160 |
30.15 |
1.15 |
25RESRC050 |
Reservatório |
100 |
127 |
27 |
1.25 |
25RESRC051 |
Reservatório |
111 |
120.36 |
9.36 |
0.81 |
and |
Reservatório |
127 |
129 |
2 |
0.97 |
and |
Reservatório |
134 |
139 |
5 |
0.82 |
and |
Reservatório |
148 |
153 |
5 |
0.91 |
25RESRC055 |
Reservatório |
Waiting for diamond tail |
|||
25RESRC056* |
Reservatório |
77 |
84 |
7 |
0.98 |
25RESRC057 |
Reservatório |
No significant results |
|||
25RESRC058* |
Reservatório |
64 |
86 |
22 |
1.51 |
25RESRC059 |
Reservatório |
20 |
25 |
5 |
1.25 |
25RESRC060 |
Reservatório |
65 |
87 |
22 |
1.35 |
and |
Reservatório |
91 |
94 |
3 |
0.68 |
and |
Reservatório |
102 |
104 |
2 |
0.97 |
and |
Reservatório |
110 |
118 |
8 |
0.89 |
25RESRC064 |
Reservatório |
25 |
47 |
22 |
1.56 |
25RESRC065 |
Reservatório |
105 |
118 |
13 |
1.11 |
and |
Reservatório |
122 |
128 |
6 |
1.08 |
*Significant results from RC hole, diamond tail to follow
** From completed diamond tail
JORC Table 1 Section 1 Sampling Techniques and Data
Criteria |
JORC Code Explanation |
Commentary |
Sampling techniques |
· Nature and quality of sampling (e.g. cut channels, random chips, or specific specialised industry standard measurement tools appropriate to the minerals under investigation, such as down hole gamma sondes, or handheld XRF instruments, etc). These examples should not be taken as limiting the broad meaning of sampling. · Include reference to measures taken to ensure sample representivity and the appropriate calibration of any measurement tools or systems used. · Aspects of the determination of mineralisation that are Material to the Public Report. In cases where 'industry standard' work has been done this would be relatively simple (e.g. 'reverse circulation drilling was used to obtain 1 m samples from which 3 kg was pulverised to produce a 30 g charge for fire assay'). In other cases more explanation may be required, such as where there is coarse gold that has inherent sampling problems. Unusual commodities or mineralisation types (e.g. submarine nodules) may warrant disclosure of detailed information. |
· The majority of previous holes were reverse circulation, sampled at 1m intervals. RC samples were collected in large plastic bags attached to the cyclone. On completion of the 1m run the large sample was passed through a 3-stage riffle splitter to collect a 2.5-4kg sub sample, to be used for assay. · Diamond holes were completed for metallurgical sampling, geotechnical analysis and resource estimation. Core was PQ/HQ size, sampled at 1m intervals in the pegmatite, with boundaries sampled to geological boundaries. Half core samples were collected for analysis. · Drilling was carried out to infill previous drilling to achieve a nominal 40m by 40m spacing with selected infill to 40m by 20m spacings, or as twins of previous RC drilling to get known samples for metallurgical testing. Geotechnical drilling was designed purely to intersect planned pit walls and pegmatite intersections were incidental, but followed all standard logging and sampling in line with all the drilling. · Collar surveys are carried using differential DGPS with an accuracy to within 0.2m. · A down hole survey for each hole was completed using gyro equipment. · The lithium mineralisation is predominantly in the form of Spodumene-bearing pegmatites, the pegmatites are unzoned and vary in thickness from 5m-109m.
|
Drilling techniques |
· Drill type (e.g. core, reverse circulation, open-hole hammer, rotary air blast, auger, Bangka, sonic, etc) and details (e.g. core diameter, triple or standard tube, depth of diamond tails, face-sampling bit or other type, whether core is oriented and if so, by what method, etc). |
• RC drilling used a 120mm diameter face sampling hammer. · Core drilling was carried out using PQ/HQ single tube core barrels.
|
Drill sample recovery |
· Method of recording and assessing core and chip sample recoveries and results assessed. · Measures taken to maximise sample recovery and ensure representative nature of the samples. · Whether a relationship exists between sample recovery and grade and whether sample bias may have occurred due to preferential loss/gain of fine/coarse material. |
· RC drilling sample weights were monitored to ensure samples were maximised. Samples were carefully loaded into a splitter and split in the same manner ensuring that the sample split to be sent to the assay laboratories were in the range of 4-6kg. · Core recovery was measured and was found to be generally excellent. · No obvious relationships between sample recovery and grade. |
Logging |
· Whether core and chip samples have been geologically and geotechnically logged to a level of detail to support appropriate Mineral Resource estimation, mining studies and metallurgical studies. · Whether logging is qualitative or quantitative in nature. Core (or costean, channel, etc) photography. · The total length and percentage of the relevant intersections logged. |
· RC holes were logged in the field at the time of sampling. Core was logged in detail for a variety of physical characteristics in a logging yard away from the drilling · Each 1m sample interval was carefully homogenised and assessed for lithology, colour, grainsize, structure and mineralisation. Core was sampled to geological boundaries and at 1m intervals therein. · A representative chip sample produced from RC drilling was washed and taken for each 1m sample and stored in a chip tray which was photographed. · Percussion holes were logged for every metre drilled with the spoil collected for each metre by shovel and placed in a sample bag, a representative sub sample was taken and logged for lithology, colour, grainsize and mineralisation. · Core was photographed. |
Sub-sampling techniques and sample preparation |
· If core, whether cut or sawn and whether quarter, half or all core taken. · If non-core, whether riffled, tube sampled, rotary split, etc and whether sampled wet or dry. · For all sample types, the nature, quality and appropriateness of the sample preparation technique. · Quality control procedures adopted for all sub-sampling stages to maximise representivity of samples. · Measures taken to ensure that the sampling is representative of the in-situ material collected, including for instance results for field duplicate/second-half sampling. · Whether sample sizes are appropriate to the grain size of the material being sampled. |
· 1m RC samples were split by the riffle splitter at the drill rig and sampled dry. · Core was cut in half using a diamond saw with 1m half core samples submitted for analysis or for metallurgical samples one of the halves was cut again for a quarter core and sent for analysis. · The sampling was conducted using industry standard techniques and were considered appropriate. · Field duplicates were used to test repeatability of the sub-sampling and were found to be satisfactory. · Every effort was made to ensure that the samples were representative and not biased in any way.
|
Quality of assay data and laboratory tests |
· The nature, quality and appropriateness of the assaying and laboratory procedures used and whether the technique is considered partial or total. · For geophysical tools, spectrometers, handheld XRF instruments, etc, the parameters used in determining the analysis including instrument make and model, reading times, calibrations factors applied and their derivation, etc. · Nature of quality control procedures adopted (e.g. standards, blanks, duplicates, external laboratory checks) and whether acceptable levels of accuracy (i.e. lack of bias) and precision have been established. |
· Samples were received, sorted, labelled, and dried. · Samples were crushed to 70% less than 2mm, riffle split off 250g, pulverise split to better than 85% passing 75 microns and 5g was split of for assaying. · The samples were analysed using ALS Laboratories ME-MS89L Super Trace method which combines a sodium peroxide fusion with ICP-MS instrumentation utilising collision/reaction cell technologies to provide the lowest detection limits available. · A prepared sample (0.2g) is added to sodium peroxide flux, mixed well and then fused in at 670°C. The resulting melt is cooled and then dissolved in 30% hydrochloric acid. This solution is then analysed by ICP-MS and the results are corrected for spectral inter-element interferences. · The final solution is then analysed by ICP-MS, with results corrected for spectral inter-element interferences. · Standards/blanks and duplicates were inserted on a 1:20 ratio for both to samples taken. · Duplicate sample regime is used to monitor sampling methodology and homogeneity. · Routine QA/QC controls for the method ME-MS89L include blanks, certified reference standards of Lithium and duplicate samples. Samples are assayed within runs or batches up to 150 samples. At the fusion stage that quality control samples are included together with the samples, so all samples follow the same procedure until the end. Fused and diluted samples are prepared for ICP-MS analysis. ICP instrument is calibrated through appropriate certified standards solutions and interference corrections to achieve strict calibration fitting parameters. Each 40-sample run is assayed with two blanks, two certified standards and one duplicate sample and results are evaluated accordingly. · A QA/QC review of all information indicated that all assays were satisfactory. |
Verification of sampling and assaying |
· The verification of significant intersections by either independent or alternative company personnel. · The use of twinned holes. · Documentation of primary data, data entry procedures, data verification, data storage (physical and electronic) protocols. · Discuss any adjustment to assay data. |
· All information was internally audited by company personnel. · During this programme no holes were twinned. · Savannah's experienced project geologists supervised all processes. · All field data is entered into a custom log sheet and then into excel spreadsheets (supported by look-up tables) at site and subsequently validated as it is imported into the centralised Access database. · Hard copies of logs, survey and sampling data are stored in the local office and electronic data is stored on the company's cloud drive. · Results were reported as Li (ppm) and were converted to a percentage by dividing by 10,000 and then to Li2O% by multiplying by 2.153. |
Location of data points |
· Accuracy and quality of surveys used to locate drill holes (collar and down-hole surveys), trenches, mine workings and other locations used in Mineral Resource estimation. · Specification of the grid system used. · Quality and adequacy of topographic control. |
· The coordinate of each drill hole was taken at the time of collecting using a handheld GPS with an accuracy of 5m. All collars were subsequently surveyed using DGPS with an accuracy of 0.2m. · The grid system used is WSG84 Zone29N. · An accurate, aerial topographic survey was obtained with accuracy of /- 0.5m. |
Data spacing and distribution |
· Data spacing for reporting of Exploration Results. · Whether the data spacing and distribution is sufficient to establish the degree of geological and grade continuity appropriate for the Mineral Resource and Ore Reserve estimation procedure(s) and classifications applied. · Whether sample compositing has been applied. |
· Drilling was carried out on an infill basis to attain on a nominal 40m by 40m and based on geological targets with selected infill to 40m by 20m. · Drill data is considered of sufficient spacing to define Measured and Indicated Mineral Resource in accordance with requirements for a DFS · Compositing to 1m will be applied prior to resource estimation. |
Orientation of data in relation to geological structure |
· Whether the orientation of sampling achieves unbiased sampling of possible structures and the extent to which this is known, considering the deposit type. · If the relationship between the drilling orientation and the orientation of key mineralised structures is considered to have introduced a sampling bias, this should be assessed and reported if material. |
· Drilling was generally carried out using angled holes, as close to perpendicular to strike as possible. All Geotech holes were drilled in various orientations to intersect planned pit walls. According to the expert (GGC - Consultants) requirements. |
Sample security |
· The measures taken to ensure sample security. |
· Samples were delivered to a courier and chain of custody is managed by Savannah. |
Audits or reviews |
· The results of any audits or reviews of sampling techniques and data. |
· Internal company auditing based on previous programmes is carried out and an external review will be carried out by the resource consultant to assure that all data collection and QA/QC procedures were conducted to industry standards. |
JORC Table 1 Section 2 Reporting of Exploration Results
Criteria |
JORC Code explanation |
Commentary |
Mineral tenement and land tenure status |
· Type, reference name/number, location and ownership including agreements or material issues with third parties such as joint ventures, partnerships, overriding royalties, native title interests, historical sites, wilderness or national park and environmental settings. · The security of the tenure held at the time of reporting along with any known impediments to obtaining a license to operate in the area. |
· All work was completed inside the Mina do Barroso project C-100. · Savannah has received written confirmation from the DGEG that under article 24 of Decree-Law no. 88/90 of March 16 being relevant justification based on the resources allocated exploited and intended, Savannah has been approved an expansion up to 250m of C100 mining concession in specific areas where a resource has been defined and the requirement for the expansion can be justified. · The entire Phase 2 includes a total of 117 drill holes. The surface access was granted by an administrative easement right defined in the C-100 mining contract, 95 of the drill holes were included in a first easement process, and the remaining 22 were subject to second easement that is still in progress. |
Exploration done by other parties |
· Acknowledgment and appraisal of exploration by other parties. |
· Limited exploration work has been carried out by previous operators. · No historic information has been included in the Mineral Resource estimates. |
Geology |
· Deposit type, geological setting and style of mineralisation. |
· The lithium mineralisation is predominantly in the form of Spodumene-bearing pegmatites which are hosted in meta-pelitic and mica schists, and occasionally carbonate schists of upper Ordovician to lower Devonian age. The pegmatites vary in thickness from 5m-109m. The pegmatites occur within the license area as discrete bodies and currently four pegmatite bodies have a resource defined on them. The pegmatites vary in orientation from large shallow dipping bodies, such as the north - south striking Grandão and the east - west trending Reservatório to steeply dipping dyke like bodies seen at NOA and Pinheiro. |
Drill hole information |
· A summary of all information material to the under-standing of the exploration results including a tabulation of the following information for all Material drill holes: · easting and northing of the drill hole collar · elevation or RL (Reduced Level - elevation above sea level in metres) of the drill hole collar · dip and azimuth of the hole · down hole length and interception depth · hole length · If the exclusion of this information is justified on the basis that the information is not Material and this exclusion does not detract from the understanding of the report, the Competent Person should clearly explain why this is the case.
|
· A table containing all drill holes drilled and a list of significant assays from the results received is included with the release. · No material data has been excluded from the release. .
|
Data aggregation methods |
· In reporting Exploration Results, weighting averaging techniques, maximum and/or minimum grade truncations (e.g. cutting of high grades) and cut-off grades are usually Material and should be stated. · Where aggregate intercepts incorporate short lengths of high-grade results and longer lengths of low grade results, the procedure used for such aggregation should be stated and some typical examples of such aggregations should be shown in detail. · The assumptions used for any reporting of metal equivalent values should be clearly stated. |
· Length weighted average grades have been reported. · No high-grade cuts have been applied to reported grades. · Metal equivalent values are not being reported; however, Li is reported as ppm and converted to the oxide Li2O for resource purposes. The conversion factor used is to divide the Li value by 10,000 and multiplying by 2.153 to represent the value as a percentage. |
Relationship between mineralisation widths and intercept lengths |
· These relationships are particularly important in the reporting of Exploration Results. · If the geometry of the mineralisation with respect to the drill hole angle is known, its nature should be reported. · If it is not known and only the down hole lengths are reported, there should be a clear statement to this effect (e.g. 'down hole length, true width not known'). |
· The majority of holes have been drilled at angles to intersect the mineralisation in perpendicular relation to the pegmatite |
Diagrams |
· Appropriate maps and sections (with scales) and tabulations of intercepts should be included for any significant discovery being reported. These should include, but not be limited to a plan view of drill hole collar locations and appropriate sectional views. |
· A relevant plan showing the drilling is included within this release.
|
Balanced Reporting |
· Accuracy and quality of surveys used to locate drill holes (collar and down-hole surveys), trenches, mine workings and other locations used in Mineral Resource estimation. · Where comprehensive reporting of all Exploration Results is not practicable, representative reporting of both low and high grades and/or widths should be practiced to avoid misleading reporting of Exploration Results. |
· All relevant results available have been previously reported. |
Other substantive exploration data |
· Other exploration data, if meaningful and material, should be reported including (but not limited to): geological observations; geophysical survey results; geochemical survey results; bulk samples - size and method of treatment; metallurgical test results; bulk density, groundwater, geotechnical and rock characteristics; potential deleterious or contaminating substances. |
· Geological mapping and rock chip sampling has been conducted over the project area. |
Further work |
· The nature and scale of planned further work (e.g. tests for lateral extensions or depth extensions or large- scale step-out drilling). · Diagrams clearly highlighting the areas of possible extensions, including the main geological interpretations and future drilling areas, provided this information is not commercially sensitive. |
· The present drill programme has been designed to infill previous drilling to attain a measured or indicated class for an upcoming resource estimation. Further work is being planned as part of a second phase of resource infill drilling. · Economic evaluation of the defined Mineral Resources, will be completed after the second phase of drilling. |